II. Proper Adjustment:
1. Set air pressure to 110 psi for incoming air from the air compressor set the FRL air gage to 85-90 psi.
2. Set oil lubricator feed to 2 for its best performance.
3. Keep all tool holders free of chips and grease, for easy to change tool.
4. If the air pressure drops below 35 psi, the unit will not work.
5. Bring the quill all the way up and lock it in place and follow step one and two.
6. Step # 1: Loosen the "X" brass nut then insert the 4mm T-wrench into the air cylinder (See Fig.1). Adjust the distance "D" between the socket and the drawbar hex to about 0.25"-0.4" (6-10 mm). Tight the "X" brass nut.
7. Step # 2: Push the air motor down by hand and release. Make sure the drawbar hex is very easily engage in the socket. Set the cap screws until it is bottom out with the stop plate. (See Fig. 2) marked “S” and “Y”

III. Operating:
1. Stop spindle completely before changing tools.
2. Quill/Spindle must be returned and locked to the top position when changing tools.
3. To change tool use a control valve to engage or disengage a tool holder.
4. Make sure that threads on drawbar or collets have sufficient thread length. About ½” – ¾”
5. Make sure the tool holder is secure before operating.
6. Do not fill oil when air lubricator is pressurized.
7. Do not use any gummy machine oil or any synthetic oil.
8. Use only professional air tool oil.
9. Do not operate if the unit failed, call the manufacturer.